The Honda EU3000iS is a 3000-watt generator with inverter technology that provides stable power for your computer, fridge, television, microwave oven or RV air conditioner.

Our Honda EU3000iS review provides a summary, it answers many questions and it also discusses the controls and operation of this 3000-watt Honda inverter generator. We see whether or not it is the best 3000-watt inverter generator that money can buy.

View and Download Honda EU3000is owner's manual online. EU3000is Portable Generator pdf manual download. Honda's advanced inverter technology provides 3,000-Watt of extremely quiet and fuel-efficient power. The eu3000is can operate a wide variety of appliances, making it perfect for use at home or camping.

2Questions and Answers

Honda EU3000iS: Summary

The Honda EU3000iS is more expensive than most other 3000-watt inverter generators, but it is more reliable and it produces less noise.

This Honda inverter generator has a dry weight of 131 pounds which is too heavy for one person to move or carry. It needs at least two people (each grabbing a handle) to move, load and unload this 3000-watt Honda generator.

It does not come with built-in wheels, but wheel kits are available. You can buy a wheel kit to make the generator easier to push around.

The Honda EU3000iS unfortunately does not have a remote starter. This is a modification you have to do at your own risk since Honda does not make a remote starter for the EU3000iS.

It is not a loud generator when you consider it has a 196cc engine. At full speed it is quieter than expected and it will not be too loud when camping out.

This Honda generator is a good entry-level choice for recreational vehicles. It can start and run up to a 13500 BTU air conditioner as well as the lights and the television. However, you might need to shut down the air conditioner if you want to use the microwave or the stove for cooking.

The Honda EU3000iS incorporates inverter technology to provide stable and reliable power for sensitive equipment such as computers.

You might find online sellers and offers for the Honda EU3000iS at Amazon.com.

Eu3000is

Questions and Answers

There are many things that people want to know about the Honda EU3000iS portable inverter generator. We have spent many hours finding questions and trying our best to answer them. We hope you find the answer you are looking for among the questions discussed below.

Does the EU3000iS have a remote start kit?

Honda does not offer a remote start kit for the Honda EU3000iS generator. You might find a generic remote start kit and install it on the generator. However, if the remote start kit causes problems with the generator it cannot be claimed under the warranty. The installation is therefore at your own risk and for your own wallet.

What is the noise level when working at full speed?

Its noise level is 58 dBA when it is working at its rated power of 2800 watts, according to the specifications provided by Honda. Watch the video below to see a sound comparison between the Honda EU3000iS and the Yamaha EF3000iSEB.

How long can it run at rated output of 2800 watts?

It runs for approximately 7 hours at its rated power on a single tank of fuel before it needs to be refueled.

Can it power a 13500 BTU RV air conditioner?

Yes, it has enough surge power to start and run most 13500 BTU air conditioners. Do not use too many other appliances when the air conditioner is running, maybe just the lights and television.

Calculate the surge and rated power requirements of the air conditioner plus the other appliances you want to run and see what the total is. You could always turn off the air conditioner when you want to use the stove or microwave to be on the safe side. The generator has its own AC circuit protector which protects the generator against accidental overloading.

Can the 12V DC output power a phone charger or inverter?

The 12-volt DC output is not regulated and may only be used for charging automotive batteries. The DC receptacle cannot be used for any other 12-volt appliance or application.

Are the handles the only way to move the generator?

No, it is not the only way to move the generator. Honda offers a swivel wheel kit for the EU3000iS inverter generator. The kit has small swivel wheels in the front and two slightly bigger wheels at the back. It seems easy enough to install (when the fuel tank is empty) and the wheels works well on hard surfaces. The wheels are too small for easy movement on rough surfaces such as grass or sand.

There is also another kit available: it is a 2-wheel kit with a telescoping handle. It has 8-inch rubber wheels at the front and a telescoping stainless steel handle at the back. This kit allows you to push the Honda EU3000iS generator forwards with the handles and the two front wheels.

What kind of plug outlets does the EU3000iS have?

It has two 120V 20A receptacles and one 120V 30A locking plug receptacle, but it does not have 220V power outlets. It has one 12V, 12A, 144W DC output for charging automotive batteries.

How well does the EU3000iS run at high altitude?

The standard carburetor setup is for operation at altitudes lower than 5000 feet (1500 meters). If you always use the generator at an altitude higher than 5000 feet, then you should let a Honda service dealer modify the carburetor.

Above 5000 feet the air becomes too thin for the standard carburetor air-fuel mixture. The mixture will be too rich with fuel. The carburetor modification changes the air-fuel mixture to the correct ratio. However, the engine will still lose about 3.5% horsepower for every 1000-foot increase in altitude. This means that you might not be able to power the same loads at a high altitude that you could power at a low altitude.

Remember to let a Honda service dealer modify the carburetor again if you ever want to use it at altitudes lower than 5000 feet to prevent the engine from overheating due to a lean air-fuel mixture.

Remote Start For Honda Eu3000is

Is it possible to run the Honda EU3000iS on propane?

Yes, it is possible to install a tri-fuel conversion kit. However, it is not recommended by either Honda, the EPA or the CARB. If any part of the generator is damaged by the conversion to propane, that part will not be covered by the warranty.

Can you connect the EU3000iS and EU2000i in parallel?

It is not possible. You may only use two similar Honda generators in parallel operation. You can only connect two Honda EU3000iS inverter generators together for parallel power.

Honda EU3000iS: Verdict

The Honda EU3000iS inverter generator is highly recommended. It might be heavy to move around, so it is worth installing the wheel kit. It is fuel efficient and can power the air conditioner of a smaller recreational vehicle, but maybe not a large RV. The Honda EU3000iS might be the best 3000-watt inverter generator on the market (find offers at Amazon.com).

P.S. You might also read this review of the Generac iQ3500 portable inverter generator. Generac says that it beats Honda! They market the iQ3500 as being more powerful and quieter than the Honda EU3000iS.

Honda Generator Eu3000is Troubleshooting Key Wont Start Problems

Eventually, all generators will have trouble starting, even Honda. (Amazon)

My Generator won’t Start, what’s wrong? This is a common problem that many generator owners eventually have. Let’s face it, for any product with an engine, eventually it won’t start. Whether it’s a chainsaw, a car or a portable generator — what do you do when your generator won’t start?

My Generator won’t Start Troubleshooting

If your generator won’t start, there could be any number of problems. I know that it can be infuriating if the power fails or you arrive at a campsite, just to find that your generator has just given up the ghost.

Dell windows 7 professional key generator. From many years of experience, I know that the problem is usually quite simple if you know what to look for. In this article, I’m going to look at the common reasons why your generator won’t start and some of the less common ones. If, after following this advice, your generator still won’t start, you might need to contact your dealership for help. Though, it’s very likely that you’ll find the cause and have your generator up and running in no time.

VIDEO How to Start Your Generator

Don’t Panic

The most common cause for a generator not starting is because of engine flooding. This means that unburned fuel has collected in the combustion chamber causing wet fuel to collect on the spark plug. If you continue to pull on the recoil starter or crank the electric starter too many times with no success, you’re just aggravating the problem.

Sometimes it’s a good idea to just wait 5-minutes and then try again.

First check that you’ve done everything correctly. The on switch must be in the correct position, otherwise there will be no spark. This may seem obvious, but you’ll be surprised how many people can forget this and then start to panic.

The fuel tap must be in the correct position and so must the choke if you’re performing a cold start. Of course, you must make sure there’s gas in the tank.

Make sure the power supply to your electrical outlets are switched off before starting your generator.

If you have a 4-stroke engine, it probably has a low oil shutoff switch – so check that the oil level is sufficient. For a 2-stroke engine, make sure you’ve mixed the oil and gas at the correct ratio.

If you’re sure that you’ve followed the correct starting procedures and your generator still won’t start, there may be a simple technical problem. Here’s how you go about addressing these generator starting issues.

VIDEO 3 things to check when your generator won’t start

Your Generator Needs Spark

If the on/off switch is in the correct position, you should have power to your spark plug, unless there’s a problem. Using a spark plug tester can simplify things. If you don’t have one, there’s a lot you can determine by a visual inspection.

Before you remove the spark plug, check the cord from the ignition coil to the spark plug. It often happens that a generator won’t start because the HT lead that conducts the current to the sparkplug has worked loose, or is damaged. If you disconnect this lead from the plug or coil, you should here a slight popping sound as you break the vacuum inside the connection. If you don’t, this means that the cord was not properly connected.

So remove the cord from either end and blow it clean to make sure there’s no debris inside that could interfere with the spark. At the same time, check for any obvious damage to the cord. If you observe any breaks or burns, replace it. After doing this try start your generator.

If your generator still won’t start, check the spark plug. Remove the spark plug and inspect it for any obvious damage. If the porcelain part is damaged, the spark plug won’t work. Carbon buildup is another common sparkplug problem. If the spark plug is black and sooty, use a small piece of sandpaper to clean the terminals.

Honda 3000is Generator Won't Start

Oil on the spark plug can also be a problem, but this is usually an indication of something more serious and your rings are probably damaged. Even then, you should be able to start your generator by removing the oil. To do this, dip the terminals in some gas and rub it off with a clean cloth. You may get the generator started by doing this, but you should get it to the dealership as soon as possible to address the root cause of the problem.

If you spark-plug is wet, but not full of oil, this means it has unburned fuel on it. You should dry the fuel by blowing onto the spark-plug (gas evaporates quickly) then replace the spark-plug.

Once you’ve checked all these elements and you still have no spark, it’s likely that your ignition coil is faulty. If this is the case, you’ll need to replace it.

If you’re sure that you’re getting a good spark at your spark-plug and your generator still won’t start, it’s time to move to the next obvious issue.

VIDEO More Tips for Starting your Portable Generator

Your Generator Needs Fuel and Air

It’s quite easy to check if fuel is reaching your carburetor, you just need to check that there’s fuel in the hose. If it’s not a clear plastic hose, you’ll need to remove the fuel hose from the carburetor and see if there’s a flow of fuel. Fuel lines can become blocked and may need to be flushed with clean gas to allow it flow to the carburetor. Sometimes it’s better to replace the fuel hose.

Honda Generator Eu3000is Troubleshooting Key Won't Start On Iphone

A dirty air filter can cause a generator not to start. A visual inspection should give you an idea as to whether you’re getting enough air into your carburetor. If you have any doubt, you can try starting the generator without an air filter. If it starts, you should clean or replace the air filter. Never run the generator without the air filter, this can damage your carburetor and possibly the engine itself. If you remove the air filter for testing purposes, switch the generator off immediately after establishing that it can start.

Honda Generator Eu3000is Troubleshooting Key Won't Start On Windows 10

A dirty carburetor is another common problem. This will often happen if you’ve stored the generator for a long period without draining the fuel from it before storage. A carburetor may also become clogged or blocked because of a lack of correct service. Use carburetor cleaner to remove any debris.

VIDEO Is It Your Low-Oil Engine Sensor? Troubleshooting Help

Electrical Malfunction

Modern generators have a few electrical components that could fail. You need to check that the on/off switch and low oil protection switch are function properly by using a multi-meter to check for continuity. Faulty switches should be replaced. Attempting to “bridge” a faulty switch is not a good idea.

You may also have a bad connection to your electric starter and you should be able to diagnose this with a visual inspection. If you’re going to replace electric wiring, make sure that you use the correct gauge – it must match the thickness of the wire that you’re replacing.

Recoil Starters

When you pull on your recoil starter, you should feel the resistance of the engine as you try start the generator. If the recoil rope is slack, it may not be engaging the flywheel and will need to be replaced.

Prevention is better than cure

Honda Generator Eu3000is Troubleshooting Key Won't Start Problems

Most of the generator starting problems that I’ve listed can be avoided with the correct care and maintenance. You should have your generator serviced by an authorized agent according to the maintenance schedule in your owner’s manual.

If you choose to service your generator yourself always use the specified grade oil in the engine and the correct filters.

Do regular visual inspections of your generator. Replacing frayed or damaged pipes and electrical wires before they become a problem will save you a lot of hassle.

Honda Generator Eu3000is Troubleshooting Key Wont Start Battery

Before storing your generator for periods of 3-months or longer, drain the fuel from the carburetor and empty the gas tank. To drain the carburetor, you simply switch the fuel tap to the off position while the engine is running. It will continue for a while and then engine will die from fuel starvation. This means there is no residual fuel in carburetor than can cause a blockage later.

Honda Eu3000is Problems

Now you know what to do if your generator won’t start…

Hopefully, after reading this article, and watching the videos you’ll no longer be asking the question : “My generator won’t start, what do I do?” My hope is that you’ll be the portable generator starting expert in your circle of friends. Learning how to start a generator that simply won’t start is valuable to know, especially during an emergency when having an operational generator is an absolute must.